• How we’re creating sustainable solutions at our Munich 2 Data Center

    • munich_sustainability_blog.jpg

Data volumes are increasing worldwide, while at the same time natural resources are increasingly becoming limited and alternative cleaner energy generation sources need to be factored into how we as operate as a purposed-led business to counter the the impacts of climate change as a sector. As a data center operator, we want to make a contribution: by 2030, we plan to operate our data centers in Europe in a climate-neutral manner, this means committing to 100% of our energy consumption being powered through renewable energy. This is an ambitious goal that we have set ourselves as part of an alliance with other data center operators and associations all committing to the Climate Neutral Data Centre Pact. Important components on the road to climate neutrality are innovation, creativity, technology. Our data center in Bavaria shows how these three factors combine to create sustainable solutions for the good of its clients, local communities, and the planet.

Munich 2 sets environmental standards

When we talk about a location advantage, we usually refer to the favourable location of our data center in terms of infrastructure and proximity to clients. These are also key arguments at our Munich 2 site in Unterschleissheim. But this data center also scores points in terms of environmental technology:

  • Groundwater cooling

    Geological tests carried out prior to the construction of the data center showed that there is a sufficiently powerful and cold groundwater flow at the Munich 2 Data Center site due to its proximity to the Alps. Together with experts and authorities, we developed a concept to use this for energy efficient cooling of the data center: Cold groundwater is pumped from a depth of around six meters at various pumping stations. In a heat exchanger, the groundwater absorbs the waste heat. The slightly heated water is then returned to the groundwater reservoir via an absorption well outside the site. It is ensured that the groundwater is completely separated from the closed cooling water circuit of the data center at all times. The temperature difference of the groundwater is permanently monitored and must not exceed a specific and technically monitored difference of seven degrees. The amount of water drawn is also limited. As soon as the quota is reached, the pump switches off automatically. This technology saves one-third of the electricity used for cooling – compared with pure cooling via conventional chillers.

In addition to this site-specific cooling option using groundwater, we use other innovative technologies in Munich 2 to operate our data center sustainably:

  • Heat recovery

    The heat generated in the data center is also used at the Munich 2 site to operate the underfloor heating, for example in offices, in the entrance area or in the stairwell for heating.

  • Rainwater utilization in the building

    Some of the rainwater is collected and used, for example, to flush toilets.

  • Rainwater infiltration

    The greater part of the rainwater is channelled into above-ground buffer storage tanks, called infiltration trenches, which have been constructed around the data center. This allows the rainwater to infiltrate over a wide area and relieves the burden on the sewage system. In addition, the extensive green roof area provides storage for extremely heavy rainfall and releases this water slowly over several days via external downpipes, also into the infiltration trenches.

All our clients at the Munich 2 site benefit from these technical innovations. Companies can also further reduce their climate impact by operating their IT systems with 100% renewable energy.

Are you looking for sustainable colocation space for your company? Come and see our innovative solutions for yourself - on request during a tour of our data center. We look forward to hearing from you: You can reach us at +49 69 7801-2110, by email at dc.emea.sales@global.ntt or via the contact form.

 